TEL: 415-242-1551
 


Batteries

   
XT Plus®
A proven generation high performance, space-saving batteries for UPS, switchgear and control
 
FEATURES AND BENEFITS
  • Longer cycle life due to use of wrapped positive plate
  • More reserve power/time in less rack space
  • Battery warranty for cycle duty, as well as float service
  • Electrical testing to 100 percent of published rating assures performance of every battery
     
  • Hardened, lead-alloy terminals or copper-inserted posts provide better conductivity and tighter connections
  • Low-maintenance, lead-calcium alloy extends watering intervals
  • Flame-retardant covers enhance battery-plant safety
  • Soft-rubber post minimizes stress on post seal

 

High-rate, bolt on intercell
connector used on 11-25
plate inserts*


 

WARRANTY CRITERIA FOR LIMITED CYCLE SERVICE
Duration of discharge
Warranted cycle life
0.0 to 0.5 minutes
0.5 to 1.5 minutes
1.5 to 4.0 minutes
4.0 to 15.0 minutes  
10,500 events
  2,100 events
     660 events
     300 events
 

Based on discharges at 15-minute rate to minimum voltage of 1.67 Vpc.


 

SPECIFICATIONS
Plates
Height
Width
Positive thickness
Negative thickness
15.62 in (397 mm)
12.62 in (321 mm)
0.20 in (5.1 mm)
0.12 in (3.0 mm)
Electrolyte height above plates
2.25 in (57 mm)
Sediment space
0.63 in (16 mm)
Electrolyte @ 77F (25C)
XT-LP
XT-LCP
Sulfuric acid, 1.215 specific gravity nominal
Sulfuric acid, 1.250 specific gravity nominal
Electrolyte withdrawal tubes
XT-LP (single and twin cell)
XT-LP (four-cell units)
2 per cell
1 per cell
Float voltages
XT-LP
XT-LCP
2.20–2.25 volts per cell
2.25–2.30 volts per cell
Container
Thermoplastic, transparent
Cover
High-impact, flame-retardant thermoplastic, with tongue-and-groove seal.
Flammability ratings: UL 94-VO; ASTM D-635, self-extinguishing. Oxygen index > 28
Separator
Microporous, with fiberglass retaining wrap
Safety vent system
Flame-arrester with dust cover
Terminals

XT-LP, and XT-LCP
(7 through 9 plates)


Two, hardened, lead-alloy chair terminals
XT-LP, and XT-LCP
(11 through 25 plates)
Two, 1-in square, copper-inserted posts with dual-bolt holes
XT-LP, and XT-LCP
(27 through 41 plates)
Four, 1-in square, copper-inserted posts with dual-bolt holes
XT-LP, and XT-LCP
(43 through 53 plates)
Six, 1-in square, copper-inserted posts with dual-bolt holes
Intercell connectors*

XT-LP, and XT-LCP
(7 through 9 plates)


Welded intercell connectors
XT-LP, and XT-LCP
(11 through 15 plates)
Bolt-on intercell connectors—5/16-in threaded-copper inserts
XT-LP, and XT-LCP
(17 through 25 plates)
Bolt-on intercell connectors—1-in square, copper- inserted posts
XT-LP, and XT-LCP
(27 through 53 plates)
N/A
Optional container
Transparent, flame-retardant polycarbonate. Oxygen index > 25.
Flammability ratings: UL 94-HB; ASTM D-635-68, self-extinguishing
*See RS-1476 for connection hardware details.


 

Models
Unit dimensions in (mm)
Unit weight lbs (kgs)
Electrolyte
per cell lbs (kgs)
L
W
H
Net filled
Dom. packed
XT4LP-7
XT4LP-9
10.08 (256) 14.12 (359) 22.75 (578) 254 (115)
304 (138)
269 (122)
319 (145)
15 (6.8)
14 (6.4)
XT4LP-11
XT4LP-13
XT4LP-15
15.00 (381) 432 (196)
482 (219)
535 (243)
 
444 (202)
499 (227)
549 (250)
  22 (10.0)
 21 (9.5)
 20 (9.1)
XT2LP-17
XT2LP-19
XT2LP-21
XT2LP-23
XT2LP-25
12.10 (307) 342 (155)
365 (166)
390 (177)
415 (139)
440 (200)
359 (163)
382 (174)
407 (185)
432 (196)
457 (208)
44 (20.0)
43 (19.5)
42 (19.1)
41 (18.2)
40 (18.2)
XT1LP-27
XT1LP-29
7.62 (194) 248 (113)
250 (118)
264 (120)
275 (125)
42 (19.1)
40 (18.2)
XT1LP-31
XT1LP-33
88.8 (226) 283 (129)
294 (134)
300 (136)
311 (141)
46 (20.9)
44 (20.0)
XT1LP-35
XT1LP-37
XT1LP-39
XT1LP-41
10.62 (270) 317 (144)
328 (149)
339 (154)
350 (159)
334 (152)
345 (157)
356 (162)
367 (167)
58 (26.4)
56 (25.5)
54 (24.5)
52 (23.6)
XT1LP-43
XT1LP-45
XT1LP-47
XT1LP-49
XT1LP-51
XT1LP-53
13.14 (334) 416 (189)
427 (194)
438 (199)
449 (204)
460 (209)
471 (214)
434 (197)
445 (202)
456 (207)
467 (212)
478 (217)
489 (222)
86 (39.1)
84 (38.2)
82 (37.3)
80 (36.4)
78 (35.5)
76 (34.5)


 

Nom.
volts
Models
Nominal rates to 1.75 Vpc average
1.215 specific gravity @ 77F (25C)
(includes connector voltage drop)
Nominal rates to 1.67 Vpc average
1.215 specific gravity @ 77F (25C)
(includes connector voltage drop)
Ampere-hours
Amperes
Kilowatts per cell
8 Hr
5 Hr
3 Hr
1 Hr
30 Min
15 Min
1 Min
1 Hr
30 Min
15 Min
1 Min
8
8
8
8
8
4
4
4
4
4
2
2
2
2
2
2
2
2
2
2
2
2
2
2
XT4LP-7 
XT4LP-9 
XT4LP-11
XT4LP-13
XT4LP-15
XT2LP-17
XT2LP-19
XT2LP-21
XT2LP-23
XT2LP-25
XT1LP-27
XT1LP-29
XT1LP-31
XT1LP-33
XT1LP-35
XT1LP-37
XT1LP-39
XT1LP-41
XT1LP-43
XT1LP-45
XT1LP-47
XT1LP-49
XT1LP-51
XT1LP-53
  291
  388
  485
  582
  679
  776
  873
  970
1067
1152
1261
1358
1455
1552
1649
1746
1843
1940
2037
2134
2231
2328
2425
2496
  279
  372
  465
  558
  651
  744
  837
  930
1023
1104
1209
1302
1395
1488
1581
1674
1767
1860
1953
2046
2139
2232
2326
2392
  265
  348
  439
  527
  610
  715
  821
  895
  983
1040
1174
1251
1354
1431
1536
1627
1716
1787
1878
1966
2035
2100
2163
2225
  198
  261
  330
  396
  457
  535
  602
  669
  736
  778
  875
  932
1009
1065
1144
1211
1278
1331
1398
1465
1515
1564
1611
1657
 295
 390
 493
 591
 683
 786
 884
 982
1081
1154
1282
1365
1478
1560
1676
1774
1872
1950
2048
2145
2219
2290
2360
2427
  397
  523
  661
  793
  916
1025
1153
1282
1410
1505
1665
1775
1922
2028
2178
2307
2434
2536
2662
2789
2885
2978
3069
3156
 554
 731
 924
1109
1280
1353
1523
1692
1861
1967
2199
2344
2538
2678
2876
3045
3214
3348
3515
3683
3809
3932
4051
4167
0.384
0.506
0.640
0.768
0.886
1.043
1.173
1.303
1.434
1.516
1.710
1.812
1.962
2.071
2.224
2.355
2.486
2.589
2.718
2.848
2.946
3.041
3.133
3.223
0.606
0.799
1.010
1.212
1.399
1.610
1.812
2.013
2.214
2.341
2.625
2.798
3.029
3.197
3.433
3.635
3.837
3.997
4.196
4.396
4.547
4.694
4.836
4.974
0.810
1.068
1.349
1.619
1.869
2.136
2.403
2.670
2.937
3.105
3.471
3.699
4.005
4.227
4.539
4.806
5.073
5.284
5.548
5.812
6.012
6.206
6.394
6.577
1.164
1.536
1.941
2.329
2.688
2.941
3.308
3.676
4.044
4.275
4.779
5.092
5.514
5.820
6.249
6.617
6.984
7.275
7.638
8.002
8.227
8.544
8.803
9.055
Note:
Data above is for 1.215 nominal specific gravity. Batteries are offered in 1.215 and 1.250 specific gravities. For batteries with 1.250 specific gravity, use indicator “C” with battery type. For example: XT4LCP-7 identifies 1.250 specific gravity. XT4LP-7 identifies 1.215 specific gravity.
 
 

 

 
 
  © Copyright 2004-2005 T&S Trading Co. All Rights Reserved.